source: trunk/hardware/sim/aktuell_schaltungsteile/kurzschlussstromSimulation.asc @ 3

Last change on this file since 3 was 1, checked in by f.jahn, 6 months ago
File size: 819 bytes
Line 
1Version 4
2SHEET 1 1012 680
3WIRE 320 80 64 80
4WIRE 544 80 400 80
5WIRE 800 80 624 80
6WIRE 992 80 880 80
7WIRE 64 128 64 80
8WIRE 64 288 64 208
9WIRE 992 288 992 80
10WIRE 1008 288 992 288
11FLAG 64 288 0
12FLAG 992 288 0
13SYMBOL voltage 64 112 R0
14WINDOW 123 0 0 Left 0
15WINDOW 39 24 124 Left 2
16SYMATTR InstName V1
17SYMATTR Value 12
18SYMATTR SpiceLine Rser=1.6m
19SYMBOL ind 896 64 R90
20WINDOW 0 5 56 VBottom 2
21WINDOW 3 32 56 VTop 2
22SYMATTR InstName L1
23SYMATTR Value 100n
24SYMBOL res 416 64 R90
25WINDOW 0 0 56 VBottom 2
26WINDOW 3 32 56 VTop 2
27SYMATTR InstName R1
28SYMATTR Value 0.5m
29SYMBOL res 640 64 R90
30WINDOW 0 0 56 VBottom 2
31WINDOW 3 66 38 VBottom 2
32SYMATTR InstName R2
33SYMATTR Value 0.179m
34TEXT 24 312 Left 2 !.tran 1m startup
35TEXT 328 -432 VRight 2 ;Beispiel R von 300A Adler AB1 Sicherung
36TEXT 568 -264 VRight 2 ;Beispiel 1Meter 95mm²
Note: See TracBrowser for help on using the repository browser.